Description
Features
General specifications:
- Measuring value error
– Standard 0.4 % of the rate, option for 0.3% and 0.2 % of the rate - Nominal diameter
– DN 3 to 2000 (1/10 to 80 in.) - Process connection
– Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129 - Nominal pressure
– PN 10 to 100,
– ASME CL 150, 300 - Lining
– Hard rubber, soft rubber, PTFE, PFA, ETFE, Linatex - IP rating
– IP67 or IP68 - Fluid temperature
– Up to 180 °C (356 °F) - Communication
– HART
– PROFIBUS DP, Profibus PA
– Modbus RTU, Modbus TCP
– Ethernet IP, Profinet- Webserver
- Ex approvals
– ATEX, IECEx, cFMus, NEPSI - Process diagnostics
– Empty pipe, partially filling, gas bubbles, electrode impedance, conductivity, sensor temperature