- Dynamic Detection Principle (DDP): Double-pass optical scattering for dust measurement; less prone to drift than standard opacity monitors
- Internal Calibration Check: Built-in electronics for easy calibration verification
- Rugged Construction: 316 stainless steel housing for durability in harsh industrial environments
- PC Software: Free utility software for setup, control, and data logging
- Alignment Tool: Dedicated button for simple, precise alignment adjustments
- Data Output & Integration: Multiple interface options for seamless integration into existing systems
- Smart Alert System: Configurable alarms to meet regulatory requirements

DSL-340 MKIII
The DSL-340 uses the innovative Dynamic Detection Principle (DDP) which measures fluctuations in the intensity of a light beam, using a folded beam Transceiver/Reflector arrangement. Increased dust or particulate density in the stack causes the amplitude of these fluctuations to increase. When calibrated against standard reference measurements, the amplitude of this signal relates directly to the dust concentration in the stack and this can be presented as a reading in mg/m³.
- Cement Plants: Monitoring dust from kilns and crushers.
- Power Plants: Tracking emissions from boilers and stacks.
- Waste Incinerators: Ensuring compliance with particulate limits.
- Pharmaceutical Plants: Controlling emissions from manufacturing processes.
- Steel & Chemical Industries: Monitoring general particulate emissions.
- Filtration Systems: Checking the performance of filter baghouses and ESPs.
- Combustion Furnaces & Boilers: Real-time monitoring of smoke and dust.
- Measuring Principle: Dynamic Detection Principle (DDP), double-pass light transmission
- Operating Wavelength: 510–540 nm (green LED)
- Measurement Reading: Concentration in mg/m³ (when calibrated)
- Measuring Range: 0–1000 mg/m³ (user selectable)
- Path Length: 0.5–10 m (flange-to-flange separation)
- Accuracy: ±2% relative to maximum range
- Resolution: 0.1 mg/m³
- Damping (Response Time): 1–60 seconds (user selectable)
- Power Supply: +24 VDC nominal (optional 90–260 VAC PSU available)
- Nominal Current: 500 mA
- Output: 4–20 mA (isolated and scalable), 2 relay contacts (3A @ 30 VDC)
- Communication: RS485 Modbus RTU, internal USB (via optional Operator Interface)
- Ambient Operating Temperature: –20 to +55 °C (air around the heads)
- Exhaust Gas Temperature: Up to +600 °C (requires heat insulating gaskets)
- Ingress Protection (IP): IP65 for measuring head; IP65/IP64/IP50 for optional Operator Interface (depending on mounting)
- Construction Materials: Rugged 316 stainless steel or aluminum (air-purged body options)