6712FR Fiberglass Refrigerated Sampler
Size (HxWxD): | 49.3 x 26 x 26 inches (125 cm x 66 x 66 cm) |
---|---|
Weight (Dry): | 160 lbs. (73 kg) |
Refrigerator Body: | Fiberglass reinforced plastic with UV-resistant gel coat |
Power Required: | 115 VAC, 60 Hz; OR 230 VAC, 50 Hz (specify) |
Pump
Intake purge: | Adjustable air purge before and after each sample. |
---|---|
Tubing life indicator: | Provides a warning to change pump tubing. |
Provides a warning to change pump tubing. | Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump tubing life: | Typically 1,000,000 pump counts |
Maximum lift: | 28 feet (8.5 m) |
Repeatability: | Typical ±5 ml or ±5% of the average volume in a set |
Typical line velocity @ Head height: | 3.0 ft./s @ 3 ft.; 2.9 ft./s @ 10 ft.; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller
Weight: | 13 lbs. (5.9 kg) |
---|---|
Size (HxWxD): | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of composite samples: | Programmable from 1 to 999 samples. |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
---|---|
Sampling modes: | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 5 sampling programs |
Sampling Stop/Resume: | Up to 24 real time/date sample stop/resume commands |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |
Standard Features
- SDI-12 interface provides “plug and play” connection with compatible measuring devices – including multi-parameter sondes from leading manufacturers.
- Standard 512KB of memory gives you great flexibility for logging environmental data.
- Corrosion-proof refrigerator cabinet is molded from polyester resin fiberglass and UV-resistant gel coat provides a smooth, non-porous finish for added protection and easy cleaning
- Heavy-duty stainless steel frame and cabinet.
- Automatic built-in heater ensures that samples won’t freeze, even when ambient temperatures drop to -20°F (-29°C).
- Durable powder-coated epoxy, phenolic paint, or polyester tubing, protects refrigeration components.
- Sample delivery at the EPA-recommended velocity of 2 ft./sec., even at head heights of 26 feet.
- Pump revolution counter and patented liquid detection sensor ensure accurate sample volumes – and tells you when tubing should be replaced.
Applications
- wastewater effluent
- storm water monitoring
- CSO monitoring
- permit compliance
- pretreatment compliance
Options and Accessories
- Composite sampling bottle configurations
- Sequential sampling bottle configurations
- ProPak disposable sample bags
- Suction lines and strainers
- 674 Rain Gauge
- 700 Series Modules for flow and parameter measurement
- Telephone Modem
- 581 RTD data retrieval device
- Cellphone based data retrieval, dial-out alarms, and remote control
- Wireless radio data retrieval with 2102 module
- Flowlink® Software
- Optional temperature sensor – provides precise log of sample compartment temperature for automatic documentation