- Oil & Gas: Measures flow in oil field operations, including water flood projects.
- High Temperature & Pressure: Handles -150° to 425°F (-101° to 218°C) and pressures up to 5000 psi.
- Corrosive & Abrasive Fluids: Durable 316 stainless steel and tungsten carbide construction for demanding fluids.
- Versatile Liquids: Suitable for hydraulic fracturing, mining, petrochemical, and irrigation applications.
- Integrated Systems: Compatible with Blancett flow monitors for measurement and reporting.

Model 1100 Turbine Flowmeter
The Model 1100 turbine flow meter is designed to withstand the demands of the most rigorous flow measurement applications. Originally developed for the secondary oil recovery market, the Model 1100 flow meter is an ideal meter for liquid flow measurement on or off the oil field.
The meter features a rugged 316 stainless steel housing and rotor support assemblies, CD4MCU stainless steel rotor, and abrasive-resistant tungsten carbide rotor shaft and journal bearings. The Model 1100 maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in oil field water flood projects and many industrial applications.
When paired with a Blancett flow monitor, the Model 1100 turbine meter meets a wide range of measurement requirements. This makes it ideal for applications such as pipelines, production/injection fields, in-situ mining operations, offshore facilities, and other industrial applications. For a full list of Blancett flow monitors, see www.badgermeter.com.
- Durable Construction: 316 stainless steel body, CD4MCU rotor, tungsten carbide shaft and bearings for corrosion and abrasion resistance.
- High Accuracy & Repeatability: ±1% of reading (for 7/8 in. and larger), ±0.1% repeatability.
- Wide Flow Range: 0.6 to 5000 gpm.
- Broad Operating Conditions: -150°F to 350°F (-101°C to 177°C) standard; up to 425°F (232°C) with high-temp options; pressures up to 5000 PSI.
- Flexible Installation: Supports pipe sizes 1/2 to 10 in.; can be mounted horizontal or vertical.
- Ease of Service: Field-replaceable internal components with no loss of accuracy.
- Connectivity: AC voltage pulse output compatible with Blancett flow monitors and K-factor scalers.
- Certifications: CSA Class I Div 1 for hazardous locations.
- NIST Traceable Calibration: Factory-calibrated for traceable accuracy.
- Flow Range: 0.6 to 5000 gpm (depends on pipe size)
- Pipe Size Range: 3/8 to 10 in. (9.5 to 254 mm)
- Accuracy: ±1% for 7/8 in. and larger; ±1% over upper 70% for smaller meters
- Repeatability: ±0.1%
- Operating Temperature: -150° to 350°F (-101° to 177°C) standard; up to 425°F (232°C) with high-temp options
- Pressure Rating: 800 psi or 5000 psi, depending on end connections
- Turndown Ratio: 10:1
- Output Signal: Flow-proportional frequency (pulse) via standard B111109 magnetic pickup