A22 ChlorLog

The A22 ChlorLog is a portable residual chlorine data logger, providing compact, stand-alone measurement and logging for use virtually anywhere within the system.

Portable Residual Chlorine Data Logger

Gathering data on residual chlorine concentrations in remote parts of water distribution systems is increasingly important. Accurate data over extended periods provides the information needed to ensure at least minimum disinfectant levels in all parts of a system. Until now, temporary chlorine residual measurement systems required the installation of standard chlorine monitors with high sample flow requirements, power connections, and separate data recording hardware. ATI has developed the “ChlorLog” to provide a compact, stand-alone measurement and logging system that can be used virtually anywhere. Sensor, electronics, data logger, and flowcell are combined in one assembly. All that’s needed is sample connection. Even sample flow control is included as part of the flow assembly.

 

Features 
  • Continuous measurement of residual chlorine
  • Sensor options for Free Chlorine, Combined Chlorine, or Total Chlorine.
  • LCD display range of 0-5.00 ppm with 0.01 ppm resolution.
  • Flowcell with integral 0.25 LPM flow control (4 GPH)
  • Sample inlet pressure 1-60 PSI (0.1-4 bar)
  • Reagent free amperometric membraned sensor.
  • 4-6 Months operation on internal replaceable batteries.
  • Programmable data storage interval from 1 second to once every 12 hours.
  • 64,000 data points maximum.
  • Free software for data download and graphing. USB download cable supplied with ChlorLog.
Key Benefits
  • Remote monitoring of residual chlorine
  • Portable for maximum flexibility
  • Combined sensor, data logger and flowcell
 
 

ChlorLog is available for a variety of applications including:

  • Gathering data on residual chlorine concentrations in remote parts of water distribution systems
  • Accurate data over extended periods
  • Compact, stand-alone measurement and logging system that can be used virtually anywhere
  • Measurement: Continuous, reagent-free, amperometric membraned sensor.
  • Chlorine Options: Free, Combined, or Total Chlorine.
  • Range & Resolution: 0–5.00 ppm with 0.01 ppm resolution.
  • Data Storage & Interval: Up to 64,000 points; programmable from 1 s to 12 h.
  • Power: 3 × ½ AA lithium batteries (4–6 months runtime).
  • Flow Control: Fixed 0.25 LPM (4 GPH) regulator.
  • Sample Pressure: 1–60 PSI (0.1–4 bar); pressure reducer needed above.
  • Data Retrieval: Free software via USB for download and graphing.
  • Enclosure: Portable, typically in foam-lined carrying case.