Sulfur Dioxide Analyzer

Get 24/7 access to your analyzer’s information with a Thermo Scientific™ iQ Series Gas Analyzer. The iQ Series Gas Analyzers are engineered to get smarter over time and help minimize troubleshooting time with a highly precise, yet tough solution. The Thermo Scientific™43iQ Sulfur Dioxide Analyzer provides the same level of performance when measuring sulfur dioxide (SO2) in ambient air up to 100ppm using pulsed fluorescence technology.

 

Description

iscover the non-stop intelligence of the iQ Series Gas Analyzer now with a two-year warranty.  Our next-generation platform of gas analyzers includes:

Predictive Diagnostics

Address problems before they occur with improved serviceability and plug-and-play components. 24/7 access to your analyzer’s information helps minimize troubleshooting time with innovative,  interchangeable DMC modules in a highly precise, yet tough solution.

Proactive Communications

Maintain optimum performance through iQ360 and email alerts. When subscribed to the iQ360 service, your instrument communicates directly to our technical support team upon alarm activation. Our technical support team develops a corrective plan and emails it to your staff. Eliminate surprises and take control of your day with the iQ Series Gas Analyzers.

Personal Device Connectivity

Real-time, continuous remote monitoring is now possible with the iQ companion mobile device app. The iQ app allows for remote monitoring of iQ gas analyzers, simplified ways of getting in touch with us, and instant access to both maintenance alerts and product documentation.

Detectable Analytes Sulfur Dioxide
Flow Rate 0.5 L/min. (standard)
Inputs 4 Isolated Voltage Inputs 0 to 10 V, 16 Digital Inputs (TTL)
Linearity ±1% full scale
Response Time 60 sec. (10 sec. average time), 110 sec. (60 sec. average time), 320 sec. (300 sec. average time)
Span Drift ±0.5% full scale (24 hr.)
Temperature (English) Operating 32°F to 113°F
Temperature (Metric) Operating 0°C to 45°C
Zero Noise 1.0 ppb RMS (10 sec. averaging time), 0.5 ppb RMS (60 sec. averaging time),0.25 ppb RMS (300 sec. averaging time)
Certifications/Compliance CE, TUV-SUD Safety, US EPA: EQSA-0486-060, UKCA
Communication Ports Serial ports:
1 RS-232/485 port
1 RS-485 external accessory port
Other ports:
3 Full speed USB ports (one in front, two in rear)
1 Gigabit Ethernet port
Communication Protocols MODBUS, streaming
Depth (English) 24 in.
Depth (Metric) 609 mm
Description 43iQ Sulfur Dioxide Analyzer
Detection Limit 2 ppb (10 second averaging time)
1 ppb (60 second averaging time)
0.25 ppb (300 second averaging time)
Electrical Requirements 100-240 VAC 50/60Hz, 275 Watts
Height (English) 8.72 in.
Height (Metric) 221.48 mm
Interferences (EPA Levels) Less than lower detectable limit except for the following:NO < 3 ppb, M-Xylene < 1ppb, H2O < 3% of reading
Measurement Range 0-10 ppm, 0-25 mg/m^3; Extended: 0 to 100 ppm, 0 to 250 mg/m3
Outputs 6 isolated analog voltages outputs, with 4 selectable ranges
6 isolated analog current outputs, with 2 selectable ranges; 8 solenoid driver outputs
10 digital reed relay contact outputs
Precision 1% of reading or 1 ppb (whichever is greater)
Weight (English) 37.1 lb.
Weight (Metric) 16.8 kg
Width (English) 16.75 in.
Width (Metric) 424.45 mm
Zero Drift <0.5 ppb (24 hour)
Unit Size Each